Slideshow Items

  • Resuscitators, Inhalators & Airway Devices
  • resuscitators-inhalators-airway-devices
Drive Medical

  |  

800cc Disposable Suction Canister Kit For Suction Machine

C$56.00
3+ Day Shipping
In store: Check availability

Available in store

UPC Code: 822383294872
SKU: 22330

Complete 800 mL disposable suction canister kit with 6-foot suction tubing, 10-inch machine tubing, elbow connector, auto shut-off lid valve, and hydrophobic filter for hygienic secretion collection with portable and stationary suction machines.

    • Why the Disposable Suction Canister Kit Is the Fluid Containment Boundary and the Suction Pump Protection Component of the Medical Suction System Simultaneously

      The 800 mL disposable suction canister kit serves two structurally distinct functions that are both essential to safe and effective medical suction operation, and that a single canister kit must satisfy simultaneously. The first function is fluid containment: the canister is the sealed vessel that receives and retains the suctioned material — mucus, saliva, blood, wound exudate, and other biological fluids — that the suction machine's vacuum draws through the suction tubing from the patient's airway or wound site. The canister must contain this material safely throughout the suction session and during removal and disposal, preventing direct contact between the caregivers and clinicians performing the suction procedure and the potentially infectious suctioned material. Medical-grade disposable plastic construction maintains the canister's structural integrity under the negative pressure differential between the canister interior — at the machine's vacuum level — and the ambient pressure outside the canister walls during the suction session. An 800 mL capacity covers the fluid volumes produced in the suction sessions for most home care and clinical airway suction applications without mid-session canister exchange — the volume threshold at which the auto shut-off lid valve activates to signal canister fullness and prevent overflow before the session's natural endpoint or before the canister is exchanged by the operator.

      The second function the canister kit must satisfy simultaneously is suction pump protection — preventing the suctioned biological material and the microorganism-containing aerosol it generates from reaching the suction machine's pump internals and exhaust output. The suction airstream that draws material from the patient into the canister continues from the canister through the machine tubing connection toward the pump — and the airstream at this stage carries aerosolised particles of the suctioned biological material that were entrained in the airflow as it passed through the canister space above the collected fluid. Without the canister kit's hydrophobic filter positioned between the canister and the machine's pump inlet, these aerosolised particles travel directly to the pump internals, where they accumulate, colonise, and progressively contaminate the device over successive suction sessions. The hydrophobic filter captures these aerosolised particles at the canister's machine-port output before they enter the pump pathway, while its hydrophobic medium prevents liquid that may splash or slosh in the canister during use from being drawn through to the machine connection. The auto shut-off lid valve provides a second level of pump protection by mechanically closing the canister's vacuum port when fluid in the canister reaches the maximum fill level — preventing the fluid level from rising to the point where liquid could be drawn through the machine tubing connection into the pump even if the operator does not respond immediately to the full-canister indication.

      The complete kit format of the 800 mL canister addresses the operational requirement of replacing the full suction collection assembly — canister, tubing, and filter — as a coordinated single-event maintenance action rather than managing individual components on separate replacement schedules. The 6-foot suction tubing is the patient-side tubing that connects the suction catheter or Yankauer handle to the collection canister, and it accumulates the same biological contamination as the canister interior during each suction session. Replacing only the canister while reusing the patient-side tubing maintains a contaminated component in the suction pathway and reduces the infection control benefit that canister disposal provides. The 10-inch machine tubing connects the canister outlet to the suction machine's inlet port, and similarly should be replaced with the canister to maintain clean connections throughout the machine-side pathway. The elbow connector provides the angular connection geometry required where the tubing connects to the canister lid in the orientation that the suction machine and collection canister positioning creates — a component whose loss or degradation would require sourcing individually without a kit format.

      The universal compatibility of the canister kit with most portable and stationary suction machines reflects the industry standardisation of the canister-to-machine interface at the collection canister's lid port dimensions. Most portable suction units — including DeVilbiss Vacu-Aide, Drive Medical, and similar devices — and most stationary clinical suction systems use a canister lid port geometry that accepts the standard collection canister's machine-side connection. This compatibility range means the kit functions as a single replacement SKU for the suction canister supply requirement across a multi-device home or facility inventory without requiring device-specific canister sourcing for each machine model in use.

      KEY FEATURES

      • 800 mL medical-grade disposable canister — sealed fluid collection vessel maintaining structural integrity under suction vacuum differential across the full 800 mL capacity, with the auto shut-off lid valve activating at maximum fill to prevent overflow before the session's endpoint
      • Auto shut-off lid valve — mechanical closure of the canister's vacuum port when fluid reaches maximum fill level, providing automatic pump overflow protection independent of operator response time to the full-canister condition
      • Hydrophobic filter — positioned between the canister outlet and the machine-side tubing connection, capturing aerosolised biological particles from the exhaust airstream and preventing liquid from being drawn through to the machine's pump inlet
      • 6-foot suction tubing — patient-side tubing of sufficient length to reach the patient from a bedside machine placement without tension, replaced with the canister for complete infection control of the suction pathway
      • 10-inch machine tubing and elbow connector — machine-side connection components providing the tubing and angular interface required between the canister outlet and the suction machine's inlet port, replaced as a complete assembly with the canister and patient-side tubing

      BENEFITS

      • Complete kit replacement addresses the full contaminated suction pathway — canister, patient-side tubing, machine-side tubing, and filter replaced together as a coordinated assembly, eliminating the contaminated component retention that individual canister-only replacement leaves in the suction pathway
      • Auto shut-off valve provides pump overflow protection independent of operator response — mechanical closure at maximum fill level prevents fluid ingress to the machine pump pathway even if the operator does not exchange the canister immediately when the full-canister condition occurs
      • Hydrophobic filter prevents biological aerosol accumulation on pump internals — captures the aerosolised particle fraction from the suction exhaust stream before it reaches the machine's pump components, protecting pump service life and preventing pathogen colonisation of the pump interior
      • 800 mL capacity covers most home care and clinical airway suction session volumes — canister volume sufficient for the fluid accumulation of typical suction sessions without mid-session canister exchange, maintaining suction continuity through the session without interruption for canister management
      • Universal compatibility with most portable and stationary suction machines — single kit specification covering the standard canister lid port geometry of most home and clinical suction units without device-specific kit sourcing

      TYPICAL APPLICATIONS

      Tracheostomy airway suction canister replacement — scheduled canister kit replacement between suction sessions in home tracheostomy care, with complete pathway replacement — canister, tubing, and filter — maintaining the infection control standard of the suction system at each exchange

      Home care suction machine maintenance — routine canister kit replacement for patients using portable home suction machines for airway secretion management, with the complete kit format simplifying the maintenance action to a single replacement event per exchange cycle

      Long-term care facility suction canister exchange — canister kit replacement between patients or at the scheduled exchange interval in long-term care facility suction equipment, with the disposable format eliminating the decontamination requirement of reusable canister systems

      Emergency suction session with high fluid volume — 800 mL capacity appropriate for acute secretion accumulation sessions requiring sustained suction, with the auto shut-off valve providing overflow protection during prolonged high-output suction events

      Multi-machine facility canister supply — universal compatibility covering most portable and stationary suction machine models in a facility inventory, allowing the kit to be stocked as a single SKU for the full range of devices without per-model canister procurement

    • No reviews yet

      Add yours

    Testimonials from Google

    See all reviews

    Your cart — 0

    You cart is currently empty

    Login

    By using our website, you agree to the use of cookies. These cookies help us understand how customers arrive at and use our site and help us make improvements. Hide this message More on cookies »