The OEM right-side metal bracket delivers precise back strap mounting for Evolution Xpresso Wide and Trillium rollators while factory-fit geometry and durable construction restore proper strap alignment eliminating loose or crooked support.

    • Why OEM Mounting Hardware Matters

      Rollator back strap brackets serve critical safety and comfort functions: they position the back strap at precise height and distance behind the seat enabling proper mid-back support during seated rest periods, secure the strap against frame preventing slippage or detachment during loading, and maintain level horizontal alignment distributing user's weight evenly across strap width. When original brackets become damaged, lost, or loosened, back straps hang crooked creating uneven support that causes user discomfort and postural stress, sag excessively reducing effective support, or detach completely during use creating fall hazard. Generic replacement brackets often fail to match Evolution's specific frame geometry resulting in improper strap positioning, inadequate thread engagement, or structural incompatibility. The Evolution OEM right-side bracket (part B04XPR) provides exact factory specifications ensuring strap mounts at correct height relative to seat surface, proper distance behind seat back maintaining user clearance, and secure attachment to frame structure through proper mounting hole alignment and thread specifications designed specifically for Xpresso Wide and Trillium Type 2 frame geometries.

      Key Features

      • OEM Factory Part: Genuine Evolution replacement bracket matching original equipment specifications
      • Right-Side Specific: Designed for right rear frame post mounting (pairs with left bracket B04XPR)
      • Dual-Model Compatibility: Fits Evolution Xpresso Wide and Trillium Type 2 rollators
      • Precise Frame Geometry: Factory-engineered dimensions ensure proper strap height and positioning
      • Rigid Metal Construction: Durable material withstands repeated loading cycles and daily use
      • Back Strap Compatible: Designed for use with Evolution back strap B03XR (Xpresso Wide & Trillium)
      • Factory Finish: Black coating matches original equipment appearance
      • Correct Thread Specifications: Mounting holes align with frame attachment points
      • Structural Integrity: Maintains strap stability under user weight loading
      • Low-Cost Repair: Affordable bracket replacement versus $400-800 rollator disposal
      • Professional Installation: Simple mounting procedure with standard tools
      • Fleet Maintenance: Essential spare part for institutional rollator refurbishment programs

      Benefits

      • Restores Proper Alignment: Eliminates crooked or sagging back strap positioning
      • Ensures Safety: Secure mounting prevents strap detachment during use
      • Maintains Comfort: Correct positioning provides effective mid-back support
      • Prevents Further Damage: Timely bracket replacement protects strap from premature wear
      • Extends Equipment Life: Simple repair avoids expensive rollator replacement
      • Cost-Effective Solution: $10-25 bracket versus $400-800 new rollator
      • Quick Repair: Minimal downtime restores rollator to service rapidly
      • Supports Fleet Management: Stock spare parts for immediate institutional repairs
      • Professional Appearance: Factory-finish bracket maintains clean rollator aesthetics
      • Prevents User Complaints: Properly mounted strap eliminates discomfort and instability
      • Enables Refurbishment: Rental agencies restore equipment between users
      • Maintains Standards: OEM quality ensures reliable long-term performance

      Clinical Applications

      ✓ Replacing damaged brackets on aging rollators (3-5+ years typical)
      ✓ Repairing brackets bent during transport or storage impacts
      ✓ Restoring missing brackets from incomplete previous repairs
      ✓ Refurbishing rental equipment between users
      ✓ Fleet maintenance in nursing homes and assisted living facilities
      ✓ Medical equipment retail repair services
      ✓ Home maintenance for DIY-capable users
      ✓ Institutional preventive maintenance programs
      ✓ Correcting improperly installed aftermarket brackets
      ✓ Upgrading older rollators during service intervals

      Usage & Application

      Damage Assessment Protocol

      Inspect existing right-side bracket for replacement indicators: bent or deformed metal preventing proper strap attachment, cracked or broken bracket structure, missing bracket entirely, stripped mounting holes preventing secure fastening, corrosion or rust compromising structural integrity, or loose mounting despite proper tightening. Additionally, assess whether back strap hangs crooked or sags on right side—often indicates failed or improperly mounted right bracket. If both brackets require replacement, order both right (B04XPR) and left (B04XPL) simultaneously.

      Compatibility Verification

      Before ordering, confirm rollator model compatibility: Evolution Xpresso Wide (all standard sizes), Evolution Trillium Type 2 (all standard sizes). Bracket specifically engineered for these models' frame geometry—do not attempt to use on other Evolution models (standard Xpresso, original Trillium Type 1) or non-Evolution rollators. If uncertain about model, check rollator identification label (typically on frame near serial number) or measure frame post diameter and spacing comparing to known specifications. Contact supplier or Evolution technical support if compatibility questions remain.

      Required Tools and Materials

      Gather necessary equipment before beginning installation: appropriate wrench or socket (verify fastener size—typically 10mm, 12mm, or 13mm depending on model year), back strap if replacing simultaneously, mild soap and water for cleaning, dry cloth, and optional thread-locking compound (blue Loctite or equivalent) to prevent future loosening. Work in well-lit area with rollator fully opened and stable.

      Pre-Installation Frame Preparation

      With rollator opened and stable, remove worn back strap from bracket area. If replacing existing damaged bracket, remove old bracket by loosening fastener(s)—typically one bolt through frame post. If bracket severely corroded, penetrating oil may facilitate removal. Once old bracket removed, inspect frame post mounting area for damage: stripped threads, cracked frame structure, or deformed mounting surface. If frame damage exists, professional frame repair or replacement rollator may be necessary—bracket alone cannot correct structural frame issues. Clean mounting area thoroughly removing rust, debris, and old thread-locking compound. Dry completely before installing new bracket.

      Right-Side Bracket Installation Procedure

      Position new right-side bracket (B04XPR) at correct location on right rear frame post. Bracket orientation critical—should align so back strap will sit at proper height (typically 8-12 inches above seat surface) and distance behind seat (adequate clearance for user's back). Thread mounting fastener through bracket and into frame post hole hand-tight initially—do not fully tighten yet. Verify bracket sits flush against frame post without gaps or misalignment. Once properly positioned, tighten fastener progressively to manufacturer specifications—typically firm hand-tight plus 1/4 turn (approximately 20-30 ft-lbs torque depending on fastener size). Do not over-tighten which may strip threads or crack bracket; under-tightening allows movement during use.

      Back Strap Remounting

      With right bracket securely installed (and left bracket verified secure), remount back strap: Position one strap end at left bracket attachment point and secure per strap design (hook-and-loop wrap, snap buckle, or sewn loop through bracket opening). Route strap horizontally across to right bracket maintaining level alignment—strap should not twist during routing. Secure right strap end to new right bracket using identical attachment method. Leave initial slack for tension adjustment. Verify strap sits horizontally when viewed from behind—uneven positioning indicates bracket height mismatch (though unlikely with OEM brackets).

      Tension Adjustment and Testing

      With strap loosely mounted on both brackets, adjust tension: Have user (or equivalent weight) sit on rollator seat and lean back against strap. Gradually increase strap tension at adjustment points until user experiences comfortable firm support without excessive rigidity. Proper tension: strap supports user's back without sagging more than 1-2 inches under load. Test by having user perform multiple sit-lean-stand cycles verifying strap remains secure, level, and comfortable. Verify right bracket shows no movement or loosening during use testing. If bracket loosens, remove and inspect for proper mounting—may require thread-locking compound.

      Bilateral Bracket Inspection

      With right bracket newly installed, inspect left bracket for similar damage: bent structure, loose mounting, stripped holes, or corrosion. If left bracket shows any compromise, replace simultaneously—imbalanced bracket strength creates uneven strap support and accelerated wear on stronger side. Stock both right (B04XPR) and left (B04XPL) brackets for complete repairs. Many institutional programs replace both brackets proactively during major service intervals regardless of visible damage—preventive maintenance approach maximizes strap support reliability.

      Fastener Thread-Locking Option

      For institutional rollators experiencing repeated bracket loosening, consider thread-locking compound application during installation: Apply small amount of blue Loctite (removable grade) to fastener threads before installation. Tighten per standard procedure. Allow compound to cure per manufacturer instructions (typically 24 hours) before full use. Thread-locking prevents vibration-induced loosening while remaining removable for future service. Never use red Loctite (permanent grade) which prevents future bracket replacement without heating/destruction.

      Height Verification for Different Users

      OEM bracket positions strap at factory-specified height suitable for average users (5'2"-5'10"). For shorter users (under 5'2"), factory height may position strap too high creating shoulder blade pressure—unfortunately, bracket mounting position fixed by frame hole location (no height adjustment). For taller users (over 5'10"), factory height may be too low providing inadequate lumbar support—same fixed limitation. If height mismatch severe, alternative rollator model with adjustable back support may be necessary. Most users find factory OEM positioning acceptable.

      Institutional Fleet Management

      For nursing homes, assisted living, or rental agencies maintaining rollator fleets, establish preventive bracket replacement schedule: Inspect all rollator brackets quarterly. Replace any showing looseness, corrosion, or deformation. Stock both right (B04XPR) and left (B04XPL) brackets in maintenance inventory—most facilities maintaining 20+ rollators stock 5-10 spare bracket pairs for immediate repairs. Track bracket replacement frequency to identify rollators with recurring issues indicating possible frame structure problems requiring equipment retirement.

      Troubleshooting Common Installation Issues

      Bracket doesn't align with frame post hole: Verify correct bracket (right vs. left) and correct model compatibility (Xpresso Wide/Trillium Type 2). If bracket is correct but doesn't align, frame may be bent or non-standard—consult professional repair service.

      Fastener won't tighten/threads stripped: Frame post threads may be stripped from previous over-tightening or corrosion. May require thread repair (helicoil insert) or professional frame welding/replacement. Never force fastener—will worsen damage.

      Bracket loosens during use: Insufficient tightening or vibration causing loosening. Retighten to proper torque. If loosening continues, apply thread-locking compound. Persistent loosening may indicate frame structural issues.

      Back strap still hangs crooked: If right bracket newly installed and properly positioned but strap remains crooked, left bracket likely improperly positioned or damaged. Inspect and replace left bracket as needed.

      Bracket position seems incorrect: OEM brackets install at factory-specified locations. If position seems wrong but bracket properly installed in frame holes, this is factory geometry—not bracket defect. Alternative: Some users misidentify rollator model (think they have Xpresso Wide but actually have standard Xpresso)—verify model before concluding position incorrect.

      Technical Specifications

      • Product Name: Evolution Back Strap Bracket - Right Side
      • Brand: Evolution (Human Care product line)
      • Part Number: B04XPR
      • Side: Right (install on right rear frame post; pairs with left bracket B04XPL)
      • Compatible Models: Evolution Xpresso Wide and Trillium Type 2 rollators
      • Incompatible Models: Standard Xpresso (non-Wide), original Trillium Type 1, other Evolution models
      • Material: Metal bracket construction with factory finish
      • Finish: Black (standard) to match original equipment
      • Mounting Type: Bolt-through attachment to frame post (fastener typically included or reused from original)
      • Thread Specifications: Matches Evolution factory frame post threading
      • Designed for Back Strap: Evolution back strap B03XR (Xpresso Wide & Trillium)
      • Installation: Professional installation recommended; DIY possible for mechanically skilled users
      • Required Tools: Wrench or socket (typically 10mm-13mm depending on model year)
      • Sold As: Each (single right-side bracket only—left bracket B04XPL sold separately)
      • Typical Price: $ (~$10-25 per bracket depending on supplier)
      • Replacement Schedule: Replace when damaged, bent, or lost; preventive replacement every 5+ years institutional use
      • Service Life: 5-10+ years typical with proper installation and maintenance
      • Weight Capacity: Supports strap at rollator's rated weight capacity (typically 300 lb)
      • OEM Quality: Factory-specification replacement ensuring proper fit and function
      • Warranty: Per Evolution/supplier warranty (verify with supplier)