Slideshow Items

  • Continence & Ostomy
  • continence-ostomy
BRD-Bard

  |  

Lubri-Sil 100% Silicone Hydrogel Coated Foley 2-Way 5cc Balloon 20Fr 12/Bx

C$549.99
3+ Day Shipping
In store: Check availability

Available in store

SKU: BRD 175820

Lubri-Sil™ combines 100% medical-grade silicone construction with hydrogel coating for reduced-friction catheterization in latex-sensitive patients requiring secure, long-term urinary drainage.

    • Why Choose Lubri-Sil™ Silicone with Hydrogel

      The 100% silicone construction eliminates latex allergy concerns while providing superior biocompatibility for extended catheterization periods. Silicone's inherent flexibility and smooth surface reduces tissue irritation compared to latex catheters. The added hydrogel coating creates an ultra-smooth, low-friction surface during insertion and removal—combining silicone's biocompatibility with hydrogel's lubricious performance. The symmetrical 5cc balloon ensures centered positioning in the bladder for reliable retention without asymmetric pressure points.

      Key Features & Benefits

      100% Medical-Grade Silicone Construction:

      • Completely latex-free for patients with rubber latex allergies or sensitivities
      • Superior biocompatibility reduces tissue reaction and encrustation buildup
      • Flexible, soft material conforms comfortably to anatomy
      • Clear shaft allows visual monitoring of urine flow and character
      • Preferred material for intermediate- to long-term catheterization (typically 2-4 weeks or per facility protocol)

      Hydrogel Coating Technology:

      • Smooth, lubricious surface activates on contact with body fluids
      • Reduces insertion force and urethral friction during placement
      • Minimizes trauma during indwelling period
      • Easier, gentler removal compared to uncoated catheters
      • May improve patient comfort throughout catheter dwell time

      20 French Sizing:

      • 6.7mm diameter provides excellent drainage capacity
      • Larger lumen size reduces clogging risk with sediment or debris
      • Ideal for patients requiring robust urine flow
      • Common size for post-operative drainage and hematuria management
      • Yellow color-coded funnel for instant size identification

      Symmetrical 5cc Balloon:

      • Balanced inflation centers catheter in bladder
      • Reduces asymmetric pressure on bladder neck
      • Secure retention without excessive balloon volume
      • 5cc capacity minimizes bladder irritation while maintaining position
      • Inflate with sterile water only (never saline)

      Large Polished Drainage Eyes:

      • Multiple smooth eyelets promote consistent, reliable flow
      • Polished edges reduce tissue irritation
      • Strategic positioning optimizes drainage efficiency
      • Minimizes risk of mucosa being drawn into openings

      Radiopaque Stripe:

      • X-ray visible for post-placement verification
      • Confirms proper positioning in challenging cases
      • Supports quality assurance and documentation protocols

      Clinical Applications

      Ideal for:

      • Patients with confirmed or suspected latex allergies
      • Intermediate- to long-term catheterization (2-4 weeks typical, per facility protocol)
      • Post-operative urinary drainage requiring larger bore
      • Hematuria or clot passage requiring robust flow
      • Patients requiring biocompatible catheter material
      • Healthcare facilities implementing latex-free protocols

      Common Clinical Settings:

      • Post-surgical urinary management
      • Acute urinary retention
      • Critical care and ICU patients
      • Patients with neurogenic bladder
      • Oncology patients with urinary complications
      • Long-term care facilities

      Silicone Advantages for Long-Term Use

      Medical-grade silicone offers distinct benefits over latex for extended catheterization:

      • Reduced encrustation: Silicone's smooth surface resists mineral deposit buildup
      • Lower infection risk: Biocompatible material may reduce bacterial adhesion
      • Less tissue reaction: Hypoallergenic properties minimize inflammatory response
      • Maintained flexibility: Silicone remains pliable throughout dwell time
      • Extended wear time: Often suitable for longer catheterization periods than latex

      Usage & Application

      Healthcare Professional Use Only

      1. Preparation: Establish sterile field; perform urethral antisepsis per facility protocol
      2. Hydrogel Activation: Coating activates on contact with body fluids or may be pre-wetted per facility preference
      3. Insertion: Insert using aseptic technique until urine flows freely
      4. Balloon Inflation: Advance slightly, inflate symmetrical balloon with exactly 5cc sterile water (never saline)
      5. Verification: Gently retract until balloon seats at bladder neck; confirm placement (radiopaque stripe visible if imaging performed)
      6. Connection: Attach to closed drainage system; secure catheter to prevent traction
      7. Monitoring: Observe for adequate drainage, balloon integrity, and signs of complications

      Catheter Maintenance:

      • Maintain closed drainage system at all times
      • Keep drainage bag below bladder level to prevent backflow
      • Monitor daily for signs of obstruction, infection, or migration
      • Replace per facility protocol or manufacturer recommendations (typically 2-4 weeks for silicone)

      Product Specifications

      • Product Type: Indwelling Foley catheter, 2-way
      • Size: 20 French (6.7mm diameter)
      • Length: Approximately 40 cm (adult standard)
      • Material: 100% medical-grade silicone with hydrogel coating
      • Balloon Capacity: 5cc symmetrical balloon (inflate with sterile water only)
      • Drainage Eyes: Large, polished multiple eyelets
      • Shaft: Clear silicone (transparent for visual monitoring)
      • Radiopacity: Radiopaque stripe for X-ray visibility
      • Color Code: Yellow funnel (20 Fr)
      • Latex Status: 100% latex-free (silicone construction)
      • Sterility: EO sterilized, single-patient use
      • Packaging: 12 catheters per box (individually sterile-wrapped)
      • Brand/Product Line: Lubri-Sil™ (100% silicone with hydrogel coating)
    • No reviews yet