Medline Latex Free Silicone Foley Catheter 2-Way Size 14Fr 10 cc

C$12.65
In stock online
In store: Check availability

Available in store

UPC Code: 40884389034430
SKU: DYND11501

This 14 Fr Foley catheter is made from 100% medical-grade silicone for latex-sensitive patients. Polished eyelets ensure smooth insertion and consistent drainage, while the 10 mL balloon provides secure bladder retention.

    • Why 100% Silicone Construction

      Unlike latex or coated catheters, pure silicone offers superior biocompatibility for patients with latex allergies or sensitivities. The naturally smooth surface reduces friction during insertion and minimizes tissue irritation throughout wear.

      Key Features & Benefits

      • 100% medical-grade silicone construction—completely latex-free and DEHP-free
      • 2-way design with drainage lumen and balloon inflation port for standard indwelling use
      • 10 mL retention balloon ensures secure positioning in the bladder
      • Polished dual drainage eyelets promote consistent urine flow and reduce urethral irritation
      • 14 French (14 Fr) size balances patient comfort with adequate drainage capacity
      • Color-coded funnel enables quick size identification in clinical settings
      • Radiopaque stripe allows X-ray visualization for placement confirmation (varies by model)
      • Sterile, single-use design prevents cross-contamination
      • Transparent material allows visual monitoring of drainage
      • Safe for patients with latex allergies or sensitivities
      • Flexible yet durable material conforms comfortably to anatomy
      • Biocompatible silicone reduces risk of allergic reactions and tissue inflammation
      • Clear size markings streamline busy clinical workflows

      Clinical Applications

      Ideal for patients requiring:Latex-free catheterization due to allergies or sensitivities ✓ Short- to intermediate-term bladder drainage (typically up to 30 days) ✓ Post-operative urinary management following abdominal, pelvic, or urological surgery ✓ Accurate urine output monitoring in critical care or perioperative settings ✓ Bladder decompression due to urinary retention or obstruction ✓ Patients with history of latex reactions or contact dermatitis ✓ Long-term catheterization requiring biocompatible materials ✓ Medication instillation or bladder irrigation procedures

      Usage & Application

      Sizing & Preparation:

      • Verify 14 Fr size matches physician order and patient needs
      • Inspect sterile packaging for integrity—discard if compromised
      • Gather all supplies: catheter, sterile gloves, drapes, antiseptic solution, lubricant, prefilled 10 mL sterile water syringe, drainage bag with tubing
      • Confirm patient has no contraindications to silicone catheterization
      • Test balloon BEFORE insertion: inflate with 10 mL sterile water, inspect for leaks or irregularities, then deflate completely
      • Ensure adequate lighting and patient privacy

      Application:

      1. Perform hand hygiene and explain procedure to patient
      2. Verify patient identity and confirm catheterization order
      3. Position patient appropriately (supine for females, supine or semi-recumbent for males)
      4. Open sterile catheter tray and establish sterile field
      5. Don sterile gloves using aseptic technique
      6. Clean urethral meatus with antiseptic solution per protocol (typically three swipes)
      7. Apply generous amount of sterile water-based lubricant to catheter tip (5-7 inches for males, 2-3 inches for females)
      8. Insert catheter gently using appropriate technique until urine flows
      9. Advance catheter an additional 1-2 inches (to hub) to ensure balloon is fully in bladder
      10. Inflate retention balloon with exactly 10 mL sterile water (never use saline)
      11. Gently pull back on catheter until resistance is felt, confirming balloon engagement at bladder neck
      12. Secure catheter to patient's inner thigh using appropriate securement device to prevent urethral traction
      13. Connect to sterile closed drainage system positioned below bladder level
      14. Document procedure, balloon volume, catheter type (100% silicone), and initial urine characteristics

      Monitoring the Catheter:

      • Check urine color, clarity, and volume regularly through transparent silicone material
      • Ensure tubing remains kink-free and drainage bag below bladder level
      • Monitor insertion site for signs of irritation, bleeding, or infection
      • Verify balloon remains inflated and catheter secure
      • Assess patient comfort and check for bladder distension
      • Maintain closed drainage system to reduce catheter-associated urinary tract infection (CAUTI) risk
      • Perform catheter care per facility protocol

      Drainage Management:

      • Empty drainage bag when 2/3 full or per facility protocol
      • Use separate, clean collection container for each patient
      • Avoid touching drainage spout to collection container
      • Wipe spout with alcohol swab after emptying
      • Document output volume, color, and characteristics
      • Report abnormal findings (hematuria, cloudiness, sediment, foul odor)

      Catheter Removal:

      1. Verify removal order from physician
      2. Perform hand hygiene and don clean gloves
      3. Disconnect from drainage system
      4. Use syringe to completely deflate balloon (withdraw all 10 mL)
      5. Verify balloon is fully deflated before removal
      6. Ask patient to take deep breath and exhale
      7. Remove catheter gently with steady, smooth motion during exhalation
      8. Inspect catheter tip to ensure it's intact
      9. Dispose per facility biohazard protocol
      10. Monitor patient's first void after removal (document time and amount)
      11. Assess for urinary retention or discomfort

      Product Specifications

      Type: Foley catheter, 2-way indwelling
      Size: 14 French (14 Fr) / 4.7 mm outer diameter
      Balloon Capacity: 10 mL (inflate with sterile water only)
      Material: 100% medical-grade silicone
      Length: Standard adult Foley length
      Tip Style: Round, straight for standard insertion
      Eyelets: Dual polished drainage eyes positioned opposite for optimal flow
      Funnel: Color-coded for 14 Fr size identification
      Radiopacity: Radiopaque stripe for X-ray visualization (varies by model)
      Transparency: Clear/translucent material for drainage visualization
      Sterility: Ethylene oxide (EO) sterilized
      Packaging: Sterile, single-use, individually packaged
      Use: Single patient use only—never reuse or resterilize
      Latex Content: Latex-free—safe for latex-sensitive patients
      DEHP: DEHP-free construction
      Packaging Options: Box quantities vary by SKU (commonly 10/box)
      Best For: Latex-sensitive patients, short- to intermediate-term catheterization

      Medline's 100% silicone Foley catheter delivers latex-free bladder drainage with superior biocompatibility, smooth insertion, and reliable 10 mL balloon retention—providing safe, comfortable catheterization for latex-sensitive patients and dependable performance clinicians trust for routine urinary management.