Slideshow Items

  • Catheters
  • continence-ostomy/catheters
  • Continence & Ostomy
  • continence-ostomy
MedLine

  |  

Catheter Foley Silicone Coated Coude Tip 2-Way 16fr 10cc Sterile

C$12.65
3+ Day Shipping
In store: Check availability

Available in store

SKU: DYND11216

The Silicone Coated Coudé Foley Catheter (16 Fr, 10 cc, 2-Way) uses an angled tip for easier insertion through obstruction. Silicone coating reduces friction and encrustation, and a 10 cc balloon ensures secure reliable indwelling drainage.

    • Why Choose the Silicone Coated Coudé Foley Catheter – 16 Fr, 10 cc?

      The 16 French size is one of the most commonly used catheter sizes in adult indwelling catheterisation, balancing drainage efficiency with patient comfort. In patients where urethral obstruction — typically from an enlarged prostate, urethral stricture, or other anatomical resistance — makes standard straight-tip insertion difficult or impossible, the coudé tip provides the clinical solution. Its upward angle follows the natural curvature of the male prostatic urethra, guiding the catheter through the zone of resistance and into the bladder without the trauma associated with forceful straight-tip insertion. The silicone coating over the latex body serves two functions: it reduces surface friction during insertion for a smoother, less traumatic passage, and it resists the mineral deposits that accumulate on the catheter surface during prolonged indwelling use — helping maintain drainage function over time. The 10 cc balloon provides greater retention stability than the standard 5 cc configuration. Large, smooth drainage eyes support efficient, unimpeded urine flow. Sterile and single-use.

      Key Features

      • Coudé (angled) tip for improved insertion through prostatic obstruction or urethral resistance
      • Silicone coating reduces insertion friction and resists encrustation during indwelling use
      • 16 French size for standard adult indwelling catheterisation
      • 10 cc balloon for robust, stable bladder retention
      • 2-way design with separate urine drainage and balloon inflation lumens
      • Large, smooth drainage eyes for efficient, unimpeded urine flow
      • Sterile, single-use design for consistent infection control

      Benefits

      • Coudé tip enables catheterisation where straight-tip insertion has been unsuccessful or is not safe
      • Silicone coating reduces urethral friction and associated trauma during insertion
      • Encrustation resistance helps maintain catheter drainage function during extended indwelling use
      • 10 cc balloon provides more stable retention than standard 5 cc configurations
      • Large drainage eyes support consistent, efficient urine drainage throughout the indwelling period
      • Sterile single-use packaging supports CAUTI prevention and clinical hygiene standards

      Clinical & Typical Applications

      Male patients with benign prostatic hyperplasia (BPH) or urethral obstruction where straight-tip catheter insertion has been unsuccessful

      Patients prone to catheter encrustation and blockage who benefit from the silicone-coated surface to extend catheter function

      Long-term catheterised patients in hospital, long-term care, or home care where encrustation resistance is a clinical management priority

      Post-urological surgery patients requiring indwelling drainage where insertion ease and encrustation resistance are both clinically relevant

      Hospital urology, emergency, and general medicine wards managing difficult catheterisations requiring a 16 Fr coudé approach

      Community and home care nurses managing catheter care for patients with documented urethral obstruction or frequent encrustation events

      Usage & Care

      Single-Use Only: This catheter is sterile and intended for single use only. Do not reuse, reprocess, or re-sterilise.

      Inspection: Check packaging integrity before use. Do not use if packaging is damaged, open, or past the expiry date.

      Insertion: Use strict aseptic technique throughout. Apply sterile lubricating gel generously to the coudé tip and catheter shaft. For male patients, orient the coudé tip upward during insertion to navigate prostatic resistance. Advance gently until urine flows freely.

      Balloon Inflation: Confirm urine flow before inflating the balloon. Inflate slowly with the recommended volume of sterile water (10 cc). Do not use air or saline. Gently retract until resistance confirms balloon positioning at the bladder neck.

      Drainage: Connect to a sterile urinary drainage bag. Secure the catheter to the inner thigh to minimise urethral traction.

      Removal: Fully deflate the balloon before removing the catheter. Never remove a Foley catheter with the balloon inflated.

      Note: Coudé catheter insertion must be performed by or under direct supervision of a trained clinician. Do not force through resistance — seek urological assessment if needed.

    • No reviews yet