Slideshow Items


StatLock Catheter Stabilization Device — adhesive anchor and locking retainer system that secures catheter tubing without sutures or tape, reducing movement, pulling, and accidental dislodgement for Foley, PICC, and central line applications.
Loading…
Catheter dislodgement and accidental removal are among the most common and preventable catheter management complications. Standard tape-based securement fails progressively as adhesion degrades with moisture, skin oil, and patient movement — the catheter migrates, tubing pulls at the insertion site, and in the worst case the catheter is partially or fully dislodged. Suture fixation avoids migration but introduces tissue trauma at placement, infection risk at the suture site, and pain on removal. StatLock provides a third option: an adhesive anchor pad that adheres to the periwound or periurethral skin and a locking retainer that mechanically holds the catheter tubing in a fixed orientation without sutures or tape-wrapped tubing. The retainer design allows controlled swivel movement in applicable Foley configurations — preventing the fulcrum effect where patient movement translates directly into catheter tugging force at the insertion or meatal contact point. Available configurations across Foley, PICC, central venous, arterial, dialysis, drainage, and multipurpose applications — the correct model must be matched to the catheter type and tubing diameter before dispensing. Some Foley versions are latex-free. Follow manufacturer instructions and clinical care plan.
✔ Adhesive anchor pad for skin placement without sutures or tape
✔ Locking retainer mechanically secures catheter tubing in fixed orientation
✔ Reduces catheter movement, migration, and accidental dislodgement
✔ Swivel design available in applicable Foley configurations for patient movement tolerance
✔ Available for Foley, PICC, central venous, arterial, dialysis, drainage, and multipurpose
✔ Some Foley versions latex-free — confirm by model before dispensing
✔ Match correct model to catheter type and tubing size before use
✔ Provides more reliable catheter securement than tape-based fixation
✔ Eliminates suture-site trauma, infection risk, and pain associated with sutured fixation
✔ Reduces catheter-related pulling and insertion-site irritation
✔ Swivel configurations reduce force transmission to insertion site during patient movement
✔ Supports cleaner, more organised catheter tubing positioning in clinical and home care
✔ Foley catheter securement in hospital, long-term care, and home care settings
✔ PICC line and central venous catheter stabilisation in clinical environments
✔ Arterial line and dialysis catheter securement during active treatment
✔ Drainage catheter stabilisation during post-surgical recovery
✔ Any catheter application where suture-free, tape-free securement is clinically indicated
Select the correct StatLock model for the catheter type and tubing diameter — using an incorrect model compromises securement effectiveness. Clean and dry the application skin site before placing the adhesive anchor pad. Secure the catheter tubing in the retainer following the model-specific locking instructions. Change the StatLock device per the manufacturer's recommended replacement schedule or when adhesion is compromised. Follow the patient's clinical care plan and institutional catheter management protocol. For home care use, ensure the caregiver or patient has received appropriate instruction from a qualified healthcare professional before applying.
Carousel items
Testimonial items
Very welcoming and informative. We went in to rent a Walker for my mom to see if she would use it. They had no rentals left so he gave us a brand new one on rental. Highly recommend this company for all your ADL needs.
Tara Maye
The rating of this product is 5 out of 5
Fantastic service and experience, from delivery to pickup we could not have asked for anything more! We rented a hospital bed, and I do not believe you would get better service anywhere. Highly recommended!
Shawn Dillon
The rating of this product is 5 out of 5
Super friendly and very helpful! Delivered the wheelchair for me, special ordered other parts and took the time to show me how to install. I recommend!
Fiona Haines
The rating of this product is 5 out of 5
Can not thank the team at Med Supplies enough for their amazing service. We were in a tough spot till we got their help. Amazing service. Kind and respectful delivery. First class all the way. Thank you again.
Jon Beatty
The rating of this product is 5 out of 5
Ordered the chair on Sunday and it arrived Monday morning. Spoke to customer service to follow up on delivery times. It was already on my front door. Excellent and helpful staff. The product is sturdy and of good quality. Thank you for your help.
H D
The rating of this product is 5 out of 5
Excellent experience - website faithfully represented what was in stock (which hasn't always been my experience with other vendors sadly), and local shipping was really fast - ordered on the weekend, received it on Monday in my case. Thank you for being
Jason Hudson
The rating of this product is 5 out of 5
0/0
You cart is currently empty
780 409-1509
Get directions