Slideshow Items

  • Catheters
  • continence-ostomy/catheters
  • Continence & Ostomy
  • continence-ostomy
Amsino International

  |  

Amsure Silicone Coated 2-Way Foley Cath, 14fr 5cc, Reinforced Tip 10/Bx

C$126.50
3+ Day Shipping
In store: Check availability

Available in store

SKU: 41014

The AMSure Silicone Coated Foley Catheter (Coudé, 14 Fr, 5 cc) is a reinforced-tip catheter that resists buckling through obstruction. Silicone coating reduces friction and a 5 cc balloon ensures secure, reliable indwelling bladder drainage.

    • Why Choose the AMSure Silicone Coated Coudé Foley Catheter?

      Standard coudé catheters can sometimes buckle or deform when encountering firm resistance — particularly in cases of significant prostatic hyperplasia, urethral stricture, or post-surgical anatomy — reducing insertion control and increasing the risk of urethral trauma. The AMSure Silicone Coated Foley Catheter is designed to address this directly. The reinforced coudé tip is structurally firmer than standard coudé designs, maintaining its angled shape and directional control even under the insertion forces required to navigate through obstruction. This reinforcement improves the reliability of successful insertion without requiring excessive force. The silicone coating on the shaft reduces surface friction for a smoother, more comfortable passage through the urethra, and the large drainage eyes support efficient, unimpeded urine flow once the catheter is positioned. The 5 cc balloon provides reliable intrabladder retention, and the 2-way lumen design separates the drainage and inflation channels. Sterile and single-use.

      Key Features

      • Coudé (angled) tip for improved insertion through prostatic obstruction or urethral resistance
      • Reinforced tip structure maintains shape and directional control under insertion force — resists buckling and kinking
      • Silicone coating reduces shaft friction for smoother, less traumatic urethral passage
      • 14 French size for standard adult indwelling catheterisation
      • 5 cc balloon for reliable, stable bladder retention
      • 2-way design with separate urine drainage and balloon inflation lumens
      • Large drainage eyes for efficient, unimpeded urine flow
      • Sterile, single-use design

      Benefits

      • Reinforced tip provides greater insertion control in cases of significant urethral resistance
      • Resists buckling under insertion force, reducing the risk of tip deformation and urethral trauma
      • Silicone coating minimises insertion friction and associated urethral irritation
      • 5 cc balloon delivers reliable bladder retention throughout indwelling use
      • Large drainage eyes support consistent, efficient urinary drainage
      • Sterile single-use packaging supports CAUTI prevention and infection control standards

      Clinical & Typical Applications

      Male patients with benign prostatic hyperplasia (BPH) or urethral obstruction where standard straight-tip or non-reinforced coudé catheters have been unsuccessful or caused trauma

      Patients with urethral strictures, post-surgical anatomy, or significant prostatic obstruction where a reinforced tip improves directional control during insertion

      Hospital urology, emergency, and general medicine wards managing difficult catheterisations where a reinforced coudé tip is clinically preferred

      Long-term catheterised patients requiring periodic coudé catheter changes where consistent, reliable insertion is a clinical management priority

      Post-urological surgery patients requiring indwelling drainage during recovery where a reinforced tip reduces insertion trauma risk

      Community and home care nurses managing catheter care for patients with documented difficult catheterisation history

      Usage & Care

      Single-Use Only: This catheter is sterile and intended for single use only. Do not reuse, reprocess, or re-sterilise.

      Inspection: Check packaging integrity before use. Do not use if packaging is damaged, open, or past the expiry date.

      Insertion: Use strict aseptic technique throughout. Apply sterile lubricating gel generously to the coudé tip and shaft. For male patients, orient the coudé tip upward to navigate the curve of the prostatic urethra. Advance gently until urine flows freely — the reinforced tip provides directional control without requiring excessive force.

      Balloon Inflation: Confirm urine flow before inflating the balloon. Inflate slowly with the recommended volume of sterile water (5 cc). Do not use air or saline. Gently retract until resistance confirms balloon positioning at the bladder neck.

      Drainage: Connect to a sterile urinary drainage bag. Secure the catheter to the inner thigh to minimise urethral traction.

      Removal: Fully deflate the balloon before removing the catheter. Never remove a Foley catheter with the balloon inflated.

      Note: Coudé catheter insertion must be performed by or under the direct supervision of a trained clinician. Seek urological assessment if resistance cannot be overcome with appropriate technique.

    • No reviews yet

      Add yours

    Testimonials from Google

    See all reviews

    Your cart — 0

    You cart is currently empty

    Login

    By using our website, you agree to the use of cookies. These cookies help us understand how customers arrive at and use our site and help us make improvements. Hide this message More on cookies »